. Can this product be used in a mobile home? Jun 28, 2017 by Since installation, I noticed that within 5 minutes in the shower (1.75 gallon per min showerhead), the temperature drops anywhere from 7 to 10 degrees. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Requires 240 volt electricity (a 30 amp breaker, with 10 gauge wire from the panel 10 year tank and parts, 1 year labour limited warranty. If the water heater is to remain idle for an extended period of time, the power and water to the appliance should be turned off to conserve energy and prevent a build-up of dangerous hydrogen gas. . A dual-element water heater uses two heating elements controlled by two separate thermostats. Water heaters are set from the factory to heat water to a maximum of 120 degrees Fahrenheit. An electronic LED system indicates element and thermostat operation. The two gas units both come in 40 and 50 gallon capacities, with an energy factor of .62. It provides more hot water and includes a self-cleaning feature for added convenience. If the water heater is new, or if youve just moved into a new home and arent familiar with the water heaters capability, its likely that the unit is undersized. I think I can use this water heater for more than 10 years. @blaisewerner. 1) Power on and heating cycle complete. DANGER: There is a hot water scald potential if the thermostat is set too high. Rheems light-duty commercial electric water heaters with Terminal Block are field convertible to meet any Light-Duty hot water application need. Rattling noise during periods of water usageInternal heat trap fittings in operation. Waiting for getting my refund from Rheem for removing their brand new defective unit ,transporting to Home depot,getting the new unit and reinstalling it back at my house by my plumber. The Lower light did not light right away. However posting my message yesterday I discovered that I am getting hot water at my sinks - It's just the showers that are the problem. It was a bit taller than the old one but only by about 2 so no problem. Checked power, reset the. Adam Dudley, kasten39828 8 Operating Instructions Safety Controls . It may save you time and cost. The link below may be able to answer you issue. . Sheath materials: Copper provides high quality corrosion protection and may be coated with tin, nickel or other protective finish. Rheems light-duty commercial electric water. Medium 6 Year 4500/4500-Watt Elements Electric Tank Water Heater-XE40M06ST45U1 - The Home Depot in my home. Many modern homes come with dual-element water heaters. This is normal for heat trap fittings when in operation and does not indicate a need for service. If you have no idea of how to choose the right element, this article may be helpful. Reinstall the insulation and access panels and turn on the circuit breaker. What make is your HW heater? If water continues to drip or flow from the temperature/pressure relief valve, you can replace it with the following steps: If water isnt coming from a fitting or the T&P relief valve, the tank is leaking. A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must be installed in the opening provided and marked for the purpose on the water heater. A: Hi JoeB and thank you for your question. Price and it working good. This is known as a flip/flop system. The upper one heats the water in the upper part of the tank first. Relief Valve Insulation Installation ! Rumbling noiseWater conditions in your home caused a build up of scale or mineral deposits on the heating elements. Finally an explanation on why the top element alone burning out can result in zero hot water even though there's a healthy lower element there. Must check every element which are parts of main after installed. If youre getting some hot water, and you can hear the unit heating, check the thermostat set point. Contact the water supplier or plumbing contractor on how to correct this. 2000-2022 Home Depot. Medium 9 Year 5500/5500-Watt Elements Electric Tank Water Heater with LED Indicator by Rheem (2169) Questions & Answers (403) Electronic LED system indicates element and thermostat operation Make sure it fits: measure your space to ensure dimensions fit WA Residents - see disclaimer below before purchasing http://www.water-heater-repair-guide.com Top has power, used a voltage meter, lights up, replaced bottom thermostat and element and voltage light don't light up, Nov 30, 2017 by This unit comes with two 4500-Watt elements and an automatic thermostat which keeps the water at the desired temperature. Watt Densities: Lower watt densities mean the element stays cooler and will last longer. If the water continues to be warm but not hot or heats very slowly, then one of the heating elements or thermostats is bad. 0000001231 00000 n
Vacation and Extended Shut-Down NOTICE: Refer to the Hydrogen Gas Caution in the Operating Instructions. experience as a licensed oil & gas technician. Relief valve producing popping noise or drainingPressure build up caused by thermal expansion in a closed system. 0000001833 00000 n
Status Lights and Diagnostics (if installed) This water heater may be equipped with status lights located on the top cavity cover. You checked the power? Water temperatures above 125F can cause severe burns or death from scalding. Never buy another water heater after the Rheem Marathon 50 Gal. Do Not Sell or Share My Personal Information. .75 Required Volt Connection 240 volt Uniform Energy Factor 0.93 Water Heater Features Overheat Protection,Self Cleaning,Temperature Pressure Relief Valve Labor Warranty 2 Year Part Warranty 9 Year Shirley Ann Lang. Check the picture to ensure proper wiring. Performance Mode: Applies only to unit when set point is between 1300F and 1400F. No it can not. I have one doing the same thing replaced everything but top element don't get hot enough to turn bottom element on, Jan 17, 2019 by For 2055 gallon models with single and double elements. READ ALL INSTRUCTIONS BEFORE USING. 0000001987 00000 n
Water is too hotThe thermostat is set too high. Isolated tank design reduces conductive heat loss. Washington Residents (Effective 1/1/23): THIS WATER HEATER DOES NOT MEET DEMAND RESPONSE REQUIREMENTS. It is a good value. Hi Rays and thank you for your question. xb```VVN
ae90\ PnC ( o(V bE CGc3P%c4F,p` ``t/A/ycEeL?_0
endstream
endobj
10 0 obj<>
endobj
11 0 obj<>
endobj
13 0 obj<>>>
endobj
14 0 obj<>
endobj
15 0 obj<>
endobj
16 0 obj<>
endobj
17 0 obj<>
endobj
18 0 obj<>
endobj
19 0 obj<>stream
Dual 5500 or dual 4500 watt copper heating elements. The purpose of these lights are to indicate the power and element status of the water heater. The water drained from the tank may be hot enough to present a scald hazard and should be directed to a suitable drain to prevent injury or damage. . Care and cleaning of the water heater. 0000001863 00000 n
Need Help? Medium 9 Year 4500/4500-Watt Elements Electric Water Heater with LED Indicator. . q/ vQZUO ]eGIl$=yaMWFlj Yeah, your lower element is broken, you just need to buy a new one and replace it. They apply to any brand water heater. . Lower element is powered by the thermostat-open leg of the upper element. The non-metallic tank eliminates rust and corrosion that leads to leaks in typical tank water heaters. Rhona Langridge. 110 v to the lower red wired line but no voltage to the black wired line. Nice appliance. Problem Possible Causes What To Do Rumbling noise Water conditions in your home caused a build up of scale or mineral deposits on the heating elements. We had 9 people at our home over Christmas and never had a hot water issue. What make and model is our water heater? The exact location is different with each manufacturer or model, but it probably has two panels -- one for the upper thermostat and one for the lower. IF YOU NEED SERVICE 1. Your manual should have a parts list in it, or you can find one online. F ! Cold water inlet temperature may be colder during the winter months. 0000008181 00000 n
If the unit has an electronic ignition and it wont fire, the ignition might require replacing. . Simple and easy to read. . oldturkey03. 0000007980 00000 n
Our comprehensive Rheem Water Heater Troubleshooting guide will explain common issues, provide tips, and show you how to read your model's error codes. thanks. . A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! But then the next day the problem returned, and now once again there seems to be no way to get the upper thermostat to engage the upper element. Thanks. Press and held the reset button for 10 seconds and the automatic shutoff cycles read more. Less than 10 years old, no deposits found in tank, no corrosion on elements. Related Parts Pages:Rheem Air Conditioner Parts, Rheem Furnace Parts, Rheem Water Heater Parts. ){xZ$/d22%
C Turn it all the way to Off, and then turn it to the On position. Reliance 606 40 Gallon electric. You checked the fuses to those lines? So, give the upper one time to heat up before checking the lower one. What Would Cause an Electric Hot Water Tank to Use More Electricity Than Normal? WARNING: If local codes require external application of insulation blanket kits the manufacturers instructions included with the kit must be carefully followed. @jrbryant so you have a water heater where the bottom element is not working? No it can not. Turn off power to the unit, if applicable, and check all pipe connections for water. Installing the water heater. (Upper element) lights lit. Contact the local electric utility. Hello , i need to replace my indirect fired , and i have a question , if i replace with a electric water heat , i will save money in the end of the year ? Brand new water heater was defective. 0000001331 00000 n
. Indicates heating element and thermostat operation. 0000023257 00000 n
@Rhona Langridge which site would that be? 0000001642 00000 n
California building code requires all new or retrofit water heaters be installed using an approved method to secure the water tank to the wall. . Replaced a less than three year old water heater of the exact same model due to the bottom rusting out. The water could be coming from a leaking tank, more common in old water heaters, a loose fitting or normal discharge from the temperature pressure T&P relief valve. If your hot water tank is only producing lukewarm water and both the elements read right and you set the temp to the hottest it can get you probably have a leak somewhere. There is no payment! Water Connections . These water heater are either complete junk or HomeDepot received a batch of crap. Peel back the insulation inside the tank to access the thermostat, according to CNET. HYDROGEN GAS IS EXTREMELY FLAMMABLE!! So I just put a new element in causetop read 240 bottom 110 so figured lower element was bad baught new one right on looked on water heater and now lower one reads nothing have checkedbreaker there fine any help! I just bought and had a plumber install yesterday a Rheem Performance Electric Hot Water Heater Plus 50 gal, 5500/5500 W heating elements, LED lights; model XE50MO9EL55U1. Typical top connection arrangement Typical side connection arrangement For increased energy efficiency, some water heaters have been supplied with a 2-3/8 section of pipe insulation. If you replaced an electric element, remove the cover to it, and check/tighten the element if necessary. This one was very straight forward to install. I have seen the lowest LED light come on showing the lower element is working. Performance Plus 50 Gal. . . 0000295269 00000 n
%PDF-1.5
%
Performance Plus Series: High Efficiency Electric, PERFORMANCE PLUS High Efficiency electric water heaters are engineered for longer life and feature an electronic LED system, 125 Edgeware Rd Unit 1, Brampton, Ontario, Canada, L6Y OP5. Before beginning the task, he should press the red reset button on the thermostat and check the electrical panel for thrown circuits. Changed lower element and Ask an Expert Home Improvement Questions HVAC Questions Rick, HVAC Supervisor Satisfied Customers Rick is online now Related HVAC Questions My water heater is not heating water. . 0000008413 00000 n
Power Upper Element Lower Element Possible light combinations and methods to determine proper function of water heater are shown below. Related Error Code Pages:Rheem Air Conditioner Error Codes, Rheem Furnace Error Codes, Rheem Water Heater Error Codes. 2. electric water. To check the lower one, I set the upper to the lowest setting (so it would shut off quickly) and then had power to the lower one. A: Hi Rays and thank you for your question. Electric Oscillating Tower Ceramic Space Heater with Remote Control CW100, Shop Box Edge Bench Outdoor Bench Cushions, Shop Milwaukee Battery Cordless Leaf Blowers, Up to 12 Adults Round-24 ft. Hard Sided Pools, Shop KHOMO GEAR Waterproof Patio Furniture Covers, Limit the Use of My Sensitive Personal Information, Do Not Sell or Share My Personal Information, Performance Plus 50 Gal. Power checks okay, top element 220v. Use the wrench to continue tightening it one-quarter to one-half of a turn. This model comes with 2 4500-Watt stainless steel heating elements. The fittings are electro zinc plated and polypropylene lined. The Rheem Performance Plus 50 Gal. . Depending on your water usage, the temperature can be lowered. O G
9k8B Feedback on the rain performance hot water heater. A tripped circuit breaker will shut down an electric heater and gas models that use electricity. Remove and clean the heating elements. Are the factory installed in/out pipes dielectric? I never want to be without hot water again. FIP x 3/4 in. A Rheem technician can check the gas valve and clean or replace it. ! I read some more on this forum about the mixing / anti-scald settings in one-handled faucets and suspect that might be where my real problem lies. 0000022393 00000 n
Quantity Add To Cart. Rheem. 0000020302 00000 n
Select the product type youd like to register below, Use our verification tool to check warranty status, Find local Rheem Pros to help with repairs and installs, Find the right fit for your family and budget with our full range of heating and cooling solutions, Explore Rheem hot water solutions designed for clean clothes, relaxing baths and happy homes, Discover the full line of Rheem commercial heating and cooling solutions designed to keep your business up and running, Find a durable, efficient, affordable Rheem water heating option for every size business and budget, Designed to extend the usable season for your pool or spa, our pool heaters are unmatched in features and benefits, From filters to generators to integrated systems for controlling your comfortwe make modern living more comfortable. This unit comes with two 4500 watt elements and an automatic thermostat which keeps the water at the desired temperature, providing faster hot water delivery. WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of water heaters thermostat. Make sure all faucets are closed. This might require a flat screwdriver placed in the slot on the adjuster. If the valve leaks because it is too loose, tighten it another quarter to half a turn. Vincent Garofalo, Blaise Werner IMPORTANT SAFETY INFORMATION. All rights reserved. racknrollapa, Feb 16, 2020 by Since replacing it involves the potential for a gas leak if not handled properly, consider calling a repair technician for the work. I went with the tall 50 gallon vs the short one as the short one seemed to have a lot of negative reviews etc. art description (as noted below) and P number of parts desired. REGULATIONS PROHIBIT THE SALE, SHIPMENT OR INSTALLATION OF THIS WATER HEATER IN A STATE THAT REQUIRES DEMAND RESPONSE WATER HEATERS. In order to drain the water heater, turn off the cold water supply. Electric medium water heater provides an ample supply of hot water for households with 2 to 4 people. I can't seem to get power to the lower element of my electric hot water heater the top one reads fine but the bottom one does not. Thank you Home Depot. Replace fuse or reset circuit breaker. Indoors and protected from freezing temperatures. If this problem starts immediately after you install or repair a water heater, a fitting is probably loose. That is in the shower, not with my better half. one, to provide the installer with the basic, directions and recommendations for the proper. Has 3 LED lights--power and 1 for each element. Pack Size 1 Wattage (watts) 5500 Finish Family Gray Minimum Temperature (F) 90 Maximum Temperature (F) 150 Water Connection Size (in.) 21 yrs on old water heater not too bad. Performance Plus 40 Gal Medium 9-Year 5500/5500-Watt Elements Electric Tank Water Heater with LED Indicator . The upper element heats the upper portion of the water column. Use of this site is subject to certain Terms Of Use. Installing the water heater. Water Temperature Setting ! Place a couple towels on the floor if replacing an element. A check valve located in the cold water inlet line can cause what is referred to as a closed water system. DANGER: Before manually operating the relief valve, make certain no one will be exposed to the hot water released by the valve. All models shipped in simultaneous configuration. Finally, if you managed to solve your issue, sharing these Rheem water heater troubleshooting tips on social media might benefit others. I use this webpage to test my water heater: http://waterheatertimer.org/How-to-test-. Remove the jacket access panel(s) and insulation. I'm totally at a loss, and talking to Rheem (I do still have warranty) is a mixed bag. Purchase the right valve for your model. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. Call us 844-262-5082 The Rheem Performance Plus is a water heater available in gas and electric models. . In the event the firm has moved, or is unavailable, refer to the telephone directory, commercial listings or local utility for qualified service assistance. John Bryant, You really should have posted this as a new question, instead of a comment in an answer a year old to get answered by more ifixit volunteers. Related Pages:pool heater quotes, home water heater installation, home pool heater installation, pool heater repair services, high efficiency pool heaters. Electrical current wont pass through a bad part. Featuring System Sentinel, a self diagnostic LED system that alerts the user to the operating status of the heater. IMPORTANT SAFETY INFORMATION. Water Heater Location Close to area of heated water demand. Wrap pipe tape clockwise around the new valves threads, and install it, tightening by hand until snug. Wait for the water heater to recover after an abnormal demand. 0000191623 00000 n
Plus, it's lightweight and perfect for replacement of an existing water heater. I ended up just turning the lower thermostat to 150 and lived with it like that as we could get by that way. ()egbG*46,3V ~5X.Ki@. Short models are available. Hot water heater is dispensing ultra-hot water. Limited Tank and Parts Warranty -9 Years, *See written warranty for complete details, Click or tap below to find an authorized Rheem dealer. C. Operating the water heater. The second one has incomplete threads on the cold side and needed to be returned. Thats what the chart in the . Stainless Steel Water Heater Supply Line, Upper Thermistor/ECO Replacement Kit for Rheem Performance Platinum Water Heaters, Indoor/Outdoor Whole House Electronic Descaler Conditioner Treatment System, EcoNet Home Comfort Wi-Fi Module for Performance Platinum Smart Electric Tank Water Heaters, 1/25 HP Hot Water Recirculating Pump with Under Sink Kit, 3/4 in. Installed myself in less than an hour and works great. The colder inlet water takes longer to heat. We are not trying to sell you anything. Performance & security by Cloudflare. Had it for about a month now. The fittings are electro zinc plated and polypropylene lined. It could be one or the other, and diagnosed by onsite technician, You will probably notice that hot water will run out.so best to have it serviced asap. This is an efficient, money-saving feature, as the water is heated in a consistent manner. Heats water quick and with luck it will last half as long as older one. Improper wiring. WARNING! 0000001748 00000 n
The basic operation of a two thermostat system (upper and lower) on an electric water heater of 240 volt supply is as follows: Only one element will come on at any one time. Either run hot water at a tap for a few minutes or through a hose attached to the drain near the bottom of the tank. It was easy to install and it works great! The upper element heats the upper portion of the water column. For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. Be sure to read and follow the warnings outlined on the label pictured below. Just installed it about 3 weeks ago, so far so good! After some troubleshooting on the phone with a multi-meter, Rheem sent a replacement upper thermostat. What could be the most likely cause? CAUTION: For your safety DO NOT attempt repair of electrical wiring, thermostat(s), heating elements or other operating controls. To dissipate such gas and to reduce risk of injury, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. In order to replace the thermostat or heating element, remove the cavity insert crossbar by following the instructions below: Turn off the power to the water heater. Initially things were fine, but when cold weather set in I started to notice very inconsistent results with my available hot water. Sufficient room to service heater. The Rheem Performance Line. Sometimes the first shower of the morning would be piping hot, but other times it would be lukewarm. CAUTION: Ensure the T&P Valve opening is not obstructed by the insulation. Weve included several safety steps in this Rheem water heater troubleshooting guide to prevent burn and shock. Insulation blankets, available to the general public, for external use on electric water heaters are not necessary. The upper and lower elements take turns heating the water, you will never have power to both at the same time. They can evaluate whether you can repair or replace your water heater. WA Most manufacturers recommend changing the lower thermostat setting, while leaving the upper thermostat at the factory setting. To replace the heating element in a Rheem water heater, the installer removes the old element and screws the new one into its place. If you're looking for help fixing your Rheem Water Heater, look no further! Pull it out quickly, insert the new element, and hand-tighten it.
National Merit Finalist 2022 Announcement Date,
Articles R